Bluelab Combo Meter User Manual

Browse online or download User Manual for Measuring instruments Bluelab Combo Meter. Bluelab Combo Meter User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 14
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
Contents page
Features 2
Bluelab Combo Meter 2
Introduction 3
Preparing for use 3
Calibration 4
Changing nutrient and
temperature display units 6
Measuring hydroponic
elements 7
Battery replacement 7
Cleaning the conductivity/
temperature probe 8
Cleaning the pH probe 9
Hydrating the pH probe 10
Storing the Bluelab
Combo Meter 10
Error messages 11
Technical speci cations 11
Troubleshooting guide 12
Bluelab pH Probe replacement 13
Bluelab probe care 13
Product guarantee 14
Limitation of liability 14
Contact details 14
Care and use guide
Page view 0
1 2 3 4 5 6 ... 13 14

Summary of Contents

Page 1 - Care and use guide

Contents pageFeatures 2Bluelab Combo Meter 2Introduction 3Preparing for use 3Calibration 4Changing nutrient andtemperature display units 6Measurin

Page 2 - Bluelab Combo Meter

English1010.0 Storing the Bluelab Combo MeterStore the Combo Meter in a cool, dry and clean place when not in use.Keep out of direct sunlight.Keep Co

Page 3 - 2.0 Preparing for use

English1112.0 Technical speci cationspH Conductivity TemperatureMeasurement range0.0 - 14.0 pH0 - 9.9 EC0 - 99 CF0 - 4950 ppm 500 (TDS)0 - 6930 ppm 7

Page 4 - 3.0 Calibration

English1213.0 Troubleshooting guideTrouble Reason CorrectionNutrient reading lowContaminated conductivity/temperature probe.Clean conductivity/tempera

Page 5 - 3.0 Calibration cont

English13pH probes do not last forever. They agethrough normal use and will eventually fail.To ensure you receive a long life from your pHprobe, pleas

Page 6

English14If you need assistance or advice - we’re here to help you.Phone: +64 7 578 0849 Fax: +64 7 578 0847Email: [email protected]

Page 7 - 6.0 Battery replacement

English2FeaturesMeasures pH, conductivity / nutrient (EC, CF, ppm 500 and ppm 700)and temperature (°C, °F)Lightweight and portable Replaceable double

Page 8

English31.0 IntroductionThe Bluelab Combo Meter has three press buttons; ‘pH / calibrate’, ‘nutrient / units’ and ‘temp / units’. The buttons have a s

Page 9

English43.0 CalibrationpH calibration is required before fi rst use to ensure that the fi rst reading is accurate.• The Bluelab Conductivity/Tempera

Page 10 - 9.0 Hydrating the pH probe

English53.0 Calibration cont.To calibrate the pHClean pH probe tip.See Section 8.0 (the pH probe does not require cleaning before the fi rst use).pH

Page 11 - 11.0 Error messages

English64.0 Changing nutrient and temperature display unitsNutrient and temperature can be displayed in different units. The units available are show

Page 12 - 13.0 Troubleshooting guide

English76.0 Battery replacementBatteries are replaced in the Bluelab Combo Meter when the low battery indicator appears on screen. The low battery ind

Page 13 - Bluelab pH Probe replacement

English87.0 Cleaning the conductivity/temperature probeCleaning the Bluelab Conductivity/Temperature ProbeCleaning the conductivity/temperature probe

Page 14 - Limitation of Liability

English98.0 Cleaning the Bluelab pH ProbeTo ensure accurate readings the pH probe tip needs to be rinsed in water after each use and cleaned prior to